Bryant mini split error code PC 01

Over-voltage or under-voltage protection. Also shown as PC01.

  • TypeProtection
  • SystemPower supply
  • Can I fix it?Homeowner checks, then maybe a tech
  • Applies toindoor display, four-character codes (newer units)

What PC 01 means on a Bryant

The DC bus or supply voltage went outside the safe window and the compressor stopped. It normally retries when voltage recovers.

On this platform, PC 01 is a protection: the system stopped or throttled itself to prevent damage; many clear on their own once conditions return to normal.

Common causes

  • Utility voltage sag or spike.
  • An undersized generator, extension cord or inverter.
  • A loose connection dropping voltage under load.
  • A failed capacitor or PFC stage on the outdoor board.

How to fix it yourself

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician.

  1. Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
  2. If you own a multimeter and are comfortable using it, measure the supply voltage at the outdoor unit's L1 and L2 terminals with the unit running. A 230 V system should read roughly 208 to 253 VAC.
  3. With power off, tighten every power connection from breaker to outdoor unit.
  4. If it happens when other big loads start, have an electrician check voltage drop on the circuit.
  5. Consider a dedicated HVAC surge protector.

Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.

When to call a technician

Normal supply voltage and tight connections with a persistent code means the outdoor board's power section.

Which Bryant units show PC 01

This page applies to Bryant Preferred 619P*B / 538P*B high wall, 619RC / 538PR cassette and Bryant multi-zone units on the indoor display, four-character codes (newer units). Bryant's own documentation lists PC 01 as "Over-voltage or under-voltage protection", the same definition used across the Midea platform (four-character codes) it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where Bryant shows this code

indoor display, four-character codes (newer units): The display shows a two-letter prefix and a two-character suffix, either together (EH60) or alternating (EH, then 60). Write both parts down; the suffix is what identifies the fault. EH and EL are indoor-side faults, EC is an outdoor-side fault, and PC is an outdoor protection: the unit stopped itself to prevent damage.

Other Bryant codes

Same part of the system as PC 01:

All Bryant error codes

PC 01 on other brands

The same characters do not always mean the same thing. Check the brand on your unit.

Questions people ask

Can I reset a Bryant PC 01 code myself?

Yes. Turn the system off at the breaker for five minutes, then restart it. If PC 01 comes back, the fault is real and needs the checks above.

Is it safe to keep running a Bryant showing PC 01?

Not repeatedly. A protection code means the unit stopped itself to prevent damage, and resetting it over and over can turn a cheap repair into a compressor failure. Reset once, check the basics, and stop if it returns.

Do I need a technician for Bryant PC 01?

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician. Normal supply voltage and tight connections with a persistent code means the outdoor board's power section.

Sources

  • Bryant 619P*B High Wall Ductless Owner's Manual OM-619PB-06 (self-diagnostic codes)
  • Carrier 40MAQ / 38MAQ and 38MHRB service manuals (identical Midea-built equipment)

Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.