Comfortmaker mini split error code E6

Communication error between indoor and outdoor units.

  • TypeFault
  • SystemCommunication
  • Can I fix it?Homeowner checks, then maybe a tech
  • Applies toDLC4 / DLF4 series, 2013 to 2015 (Gree-built)

What E6 means on a Comfortmaker

The indoor and outdoor control boards talk to each other continuously over the signal conductor in the interconnect cable. This code means that conversation has stopped. It is one of the most common codes on a new installation and almost always a wiring problem, not a failed board.

On this platform, E6 is a fault: something has failed or is disconnected and needs diagnosis.

Common causes

  • Interconnect wires not landed in the same order at both ends (a swapped signal and neutral is the classic).
  • A loose or backed-out terminal screw, or a strand of wire not fully under the screw.
  • A damaged, spliced or undersized communication cable (it must be a continuous run of the correct gauge).
  • No power at the outdoor unit: a tripped breaker, an open disconnect or a blown fuse.
  • A failed outdoor control board or a blown board fuse, often after a lightning event or a power surge.

How to fix it yourself

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician.

  1. Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
  2. Confirm the outdoor unit actually has power. Check the breaker, the disconnect and any fuse in the disconnect box.
  3. With power off, open the terminal covers on both units and check the interconnect wiring. Each numbered terminal must land on the same number at both ends, every strand must be under its screw, and there must be no splices, nicks or reversed conductors.
  4. Make sure the communication wire is a solid, continuous run of the gauge the manual specifies. Extending it with a wire nut or using a lighter gauge is a frequent cause of intermittent errors.
  5. If you own a multimeter and are comfortable using it, measure the supply voltage at the outdoor unit's L1 and L2 terminals with the unit running. A 230 V system should read roughly 208 to 253 VAC.
  6. If the wiring checks out and the outdoor unit has power, look for LED fault lights on the outdoor control board (behind the service panel). A dark board with good supply voltage usually means a blown board fuse or a dead board.
  7. On Gree-built units, also check the small jumper (see C5) and that the outdoor board's status LED is lit.

Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.

When to call a technician

Call a technician if the wiring is verified correct and the outdoor unit has power but the code persists. Board diagnosis needs the service manual and a meter.

Which Comfortmaker units show E6

This page applies to Comfortmaker DLCSRA / DLCSRB / DLCLRA outdoor with DLFSHA / DLFSFA indoor (2015 and later) and DLC4 / DLF4 (2013 to 2015) units on the DLC4 / DLF4 series, 2013 to 2015 (Gree-built). Comfortmaker's own documentation lists E6 as "Communication error between indoor and outdoor units", the same definition used across the Gree platform it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where Comfortmaker shows this code

DLC4 / DLF4 series, 2013 to 2015 (Gree-built): The code shows on the indoor unit's display in place of the temperature. If the display is off, press the Light button on the remote. Some models also count out the code as indicator blinks. E codes are system protections and faults, F codes are mostly sensor faults, H codes are outdoor and compressor protections, U codes are motor and valve faults, and P codes are power-supply faults.

Other Comfortmaker codes

Same part of the system as E6:

All Comfortmaker error codes

E6 on other brands

The same characters do not always mean the same thing. Check the brand on your unit.

Questions people ask

Can I reset a Comfortmaker E6 code myself?

Yes. Turn the system off at the breaker for five minutes, then restart it. If E6 comes back, the fault is real and needs the checks above.

Is it safe to keep running a Comfortmaker showing E6?

The unit will usually refuse to run, or run with reduced output, until the fault is cleared. Repeated resets do not fix anything and can mask a problem that is getting worse.

Do I need a technician for Comfortmaker E6?

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician. Call a technician if the wiring is verified correct and the outdoor unit has power but the code persists. Board diagnosis needs the service manual and a meter.

Sources

  • ICP DLCSRA Outdoor Unit Single Zone Ductless Service Manual 32808000801 (error code table)
  • ICP ductless installation instructions IM-KSAIC04-04 (DLCPRA / DLCSRB / DLCERB / DLCLRA error codes)
  • ICP R-410A Ductless Split System Service Manual 421 01 9204 00 (DLC4 / DLF4, 2013)

Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.