DIY HVAC Tools

Cooper & Hunter mini split error code LE

Compressor stall (locked rotor).

  • TypeProtection
  • SystemCompressor / inverter
  • Can I fix it?Technician job

What LE means on a Cooper & Hunter

The compressor stopped turning while it was supposed to be running.

On this platform, LE is a protection: the system stopped or throttled itself to prevent damage; many clear on their own once conditions return to normal.

Common causes

  • A seized or failing compressor.
  • A failed inverter drive.
  • Liquid refrigerant flooding.
  • Supply voltage collapsing under load.

How to fix it yourself

Do the reset and the visual checks, but the underlying repair needs a technician with a meter and the service manual.

  1. Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
  2. If you own a multimeter and are comfortable using it, measure the supply voltage at the outdoor unit's L1 and L2 terminals with the unit running. A 230 V system should read roughly 208 to 253 VAC.

Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.

When to call a technician

Technician diagnosis of the compressor and drive.

Which Cooper & Hunter units show LE

This page applies to Cooper & Hunter Sophia, Astoria, Olivia, Dakota, Hyper Heat, Alice and MIA units. Cooper & Hunter's own documentation lists LE as "Compressor stall (locked rotor)", the same definition used across the Gree platform it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where Cooper & Hunter shows this code

The code shows on the indoor unit's display in place of the temperature. If the display is off, press the Light button on the remote. Some models also count out the code as indicator blinks. E codes are system protections and faults, F codes are mostly sensor faults, H codes are outdoor and compressor protections, U codes are motor and valve faults, and P codes are power-supply faults.

Other Cooper & Hunter codes

Same part of the system as LE:

All Cooper & Hunter error codes

LE on other brands

The same characters do not always mean the same thing. Check the brand on your unit.

Questions people ask

Can I reset a Cooper & Hunter LE code myself?

Yes. Turn the system off at the breaker for five minutes, then restart it. If LE comes back, the fault is real and needs the checks above.

Is it safe to keep running a Cooper & Hunter showing LE?

Not repeatedly. A protection code means the unit stopped itself to prevent damage, and resetting it over and over can turn a cheap repair into a compressor failure. Reset once, check the basics, and stop if it returns.

What will a technician check for LE?

Technician diagnosis of the compressor and drive. Ask for the measurements, not just a parts quote.

Sources

  • Cooper & Hunter error code list and owner's manuals
  • Gree residential split service manuals

Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.