Inverter module (IPM) malfunction. Also shown as PC00.

  • TypeProtection
  • SystemCompressor / inverter
  • Can I fix it?Technician job
  • Applies toindoor unit display (four-character codes)

What PC 00 means on a Klimaire

The inverter power module that drives the compressor reported over-current, over-temperature or an internal fault. The outdoor unit shuts down to protect itself.

On this platform, PC 00 is a protection: the system stopped or throttled itself to prevent damage; many clear on their own once conditions return to normal.

Common causes

  • A blocked outdoor coil or failed fan overheating the module.
  • Low or unstable supply voltage.
  • A failing compressor drawing excess current.
  • A failed IPM or outdoor board.
  • Loose compressor terminals.

How to fix it yourself

Do the reset and the visual checks, but the underlying repair needs a technician with a meter and the service manual.

  1. Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
  2. Look at the outdoor unit: clear leaves, cottonwood fluff, snow or ice from the coil and make sure the fan can spin freely and nothing is stacked against the cabinet.
  3. If you own a multimeter and are comfortable using it, measure the supply voltage at the outdoor unit's L1 and L2 terminals with the unit running. A 230 V system should read roughly 208 to 253 VAC.
  4. If it trips only on the hottest afternoons, clean the outdoor coil thoroughly.
  5. Do not keep resetting; repeated trips can damage the compressor.

Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.

When to call a technician

Technician diagnosis: compressor windings, module output, DC bus voltage.

Which Klimaire units show PC 00

This page applies to Klimaire KSIV / KSIE / KSIO single-zone, KSIM / KMIR multi-zone and KSID / KDIP ducted units on the indoor unit display (four-character codes). Klimaire's own documentation lists PC 00 as "Inverter module (IPM) malfunction", the same definition used across the Midea platform (four-character codes) it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where Klimaire shows this code

indoor unit display (four-character codes): The display shows a two-letter prefix and a two-character suffix, either together (EH60) or alternating (EH, then 60). Write both parts down; the suffix is what identifies the fault. EH and EL are indoor-side faults, EC is an outdoor-side fault, and PC is an outdoor protection: the unit stopped itself to prevent damage.

Other Klimaire codes

Same part of the system as PC 00:

All Klimaire error codes

PC 00 on other brands

The same characters do not always mean the same thing. Check the brand on your unit.

Questions people ask

Can I reset a Klimaire PC 00 code myself?

Yes. Turn the system off at the breaker for five minutes, then restart it. If PC 00 comes back, the fault is real and needs the checks above.

Is it safe to keep running a Klimaire showing PC 00?

Not repeatedly. A protection code means the unit stopped itself to prevent damage, and resetting it over and over can turn a cheap repair into a compressor failure. Reset once, check the basics, and stop if it returns.

What will a technician check for PC 00?

Technician diagnosis: compressor windings, module output, DC bus voltage. Ask for the measurements, not just a parts quote.

Sources

  • Klimaire KSIO series service manual
  • Klimaire KSIM multi-zone service manual
  • Klimaire KMIR series troubleshooting guide

Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.