Fujitsu mini split error code E:86
Pressure sensor or pressure switch fault. Also shown as E86, 86.
- TypeFault
- SystemControl board
- Can I fix it?Technician job
What E:86 means on a Fujitsu
A pressure sensor or switch is open or reading wrong.
On this platform, E:86 is a fault: something has failed or is disconnected and needs diagnosis.
Common causes
- A failed sensor or switch.
- A loose connector.
How to fix it yourself
Do the reset and the visual checks, but the underlying repair needs a technician with a meter and the service manual.
- Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.
- With power off, reseat the pressure sensor connector on the outdoor board.
Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.
When to call a technician
Technician job.
Which Fujitsu units show E:86
This page applies to Fujitsu Halcyon, Halcyon XLTH and Airstage multi-zone units. Fujitsu's own documentation lists E:86 as "Pressure sensor or pressure switch fault", the same definition used across the Fujitsu General it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.
Where Fujitsu shows this code
Units with a display show the code as E:xx (E:41). Wall units without one flash the Operation and Timer lamps: count the Operation flashes for the first digit and the Timer flashes for the second, so 4 Operation flashes then 1 Timer flash is E:41. A wired controller shows the code directly. 1x codes are communication faults, 2x are configuration and combination errors, 3x and 4x are indoor board, sensor and fan faults, 6x and 7x are outdoor board and sensor faults, 9x are compressor and fan faults, and Ax codes are temperature and pressure protections.
Other Fujitsu codes
Same part of the system as E:86:
E:86 on other brands
The same characters do not always mean the same thing. Check the brand on your unit.
- Rheem E:86 Pressure sensor or pressure switch fault
Questions people ask
Can I reset a Fujitsu E:86 code myself?
Yes. Turn the system off at the breaker for five minutes, then restart it. If E:86 comes back, the fault is real and needs the checks above.
Is it safe to keep running a Fujitsu showing E:86?
The unit will usually refuse to run, or run with reduced output, until the fault is cleared. Repeated resets do not fix anything and can mask a problem that is getting worse.
What will a technician check for E:86?
Technician job. Ask for the measurements, not just a parts quote.
Sources
- Fujitsu General service manuals (error code tables)
- Fujitsu operating manuals (lamp-flash diagnosis)