DIY HVAC Tools

Tempstar mini split error code LP

Indoor and outdoor unit mismatch.

  • TypeFault
  • SystemOperation
  • Can I fix it?Homeowner checks, then maybe a tech
  • Applies toDLC4 / DLF4 series, 2013 to 2015 (Gree-built)

What LP means on a Tempstar

The indoor and outdoor units do not recognise each other as a compatible pair.

On this platform, LP is a fault: something has failed or is disconnected and needs diagnosis.

Common causes

  • Units from different series or capacities paired together.
  • A replacement board programmed for the wrong model.
  • On multi-zone systems, an unsupported combination of indoor units.

How to fix it yourself

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician.

  1. Check the model numbers on both units against the manufacturer's compatibility list.
  2. Reset the system: switch the breaker (or the outdoor disconnect) off, wait a full five minutes so the boards fully discharge, then switch it back on and restart from the remote.

Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.

When to call a technician

If the pairing is listed as compatible, a technician needs to check the board programming.

Which Tempstar units show LP

This page applies to Tempstar DLCSRA / DLCSRB / DLCLRA outdoor with DLFSHA / DLFSFA indoor (2015 and later) and DLC4 / DLF4 (2013 to 2015) units on the DLC4 / DLF4 series, 2013 to 2015 (Gree-built). Tempstar's own documentation lists LP as "Indoor and outdoor unit mismatch", the same definition used across the Gree platform it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.

Where Tempstar shows this code

DLC4 / DLF4 series, 2013 to 2015 (Gree-built): The code shows on the indoor unit's display in place of the temperature. If the display is off, press the Light button on the remote. Some models also count out the code as indicator blinks. E codes are system protections and faults, F codes are mostly sensor faults, H codes are outdoor and compressor protections, U codes are motor and valve faults, and P codes are power-supply faults.

Other Tempstar codes

Same part of the system as LP:

All Tempstar error codes

LP on other brands

The same characters do not always mean the same thing. Check the brand on your unit.

Questions people ask

Can I reset a Tempstar LP code myself?

Yes. Turn the system off at the breaker for five minutes, then restart it. If LP comes back, the fault is real and needs the checks above.

Is it safe to keep running a Tempstar showing LP?

The unit will usually refuse to run, or run with reduced output, until the fault is cleared. Repeated resets do not fix anything and can mask a problem that is getting worse.

Do I need a technician for Tempstar LP?

Work through the checks below first; they resolve most cases. If they do not, the repair itself may need a technician. If the pairing is listed as compatible, a technician needs to check the board programming.

Sources

  • ICP DLCSRA Outdoor Unit Single Zone Ductless Service Manual 32808000801 (error code table)
  • ICP ductless installation instructions IM-KSAIC04-04 (DLCPRA / DLCSRB / DLCERB / DLCLRA error codes)
  • ICP R-410A Ductless Split System Service Manual 421 01 9204 00 (DLC4 / DLF4, 2013)

Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.