Tempstar mini split error code P3
Outdoor temperature too low protection (heating lockout).
- TypeProtection
- SystemOperation
- Can I fix it?Usually a homeowner fix
- Applies toDLC/DLF series, 2015 and later (Midea-built)
What P3 means on a Tempstar
The outdoor temperature is below the unit's rated operating range, so the board is holding the compressor off to protect it. This is normal behavior, not a fault, on units that are not rated for your climate.
On this platform, P3 is a protection: the system stopped or throttled itself to prevent damage; many clear on their own once conditions return to normal.
Common causes
- Outdoor temperature below the unit's heating (or cooling) limit.
- The outdoor ambient sensor (T4) reading far too low, faking a cold snap.
How to fix it yourself
You can almost always clear this yourself with the steps below.
- Check the rated operating range in your manual. Many base-model units stop heating around 5°F and stop cooling below about 32°F to 40°F.
- Wait for the temperature to come back into range; the unit resumes on its own.
- If it is not actually that cold outside, suspect the T4 ambient sensor (see F1).
Switch off power at the breaker before opening either unit. Capacitors in the outdoor unit hold a charge for several minutes after power is cut.
When to call a technician
No technician needed unless the code appears at temperatures well inside the rated range.
Which Tempstar units show P3
This page applies to Tempstar DLCSRA / DLCSRB / DLCLRA outdoor with DLFSHA / DLFSFA indoor (2015 and later) and DLC4 / DLF4 (2013 to 2015) units on the DLC/DLF series, 2015 and later (Midea-built). Tempstar's own documentation lists P3 as "Outdoor temperature too low protection (heating lockout)", the same definition used across the Midea platform (classic codes) it is built on. If your unit shows a code with a different shape (for example a four-character code, or a plain number), it is from a different table; use the lookup with your exact code.
Where Tempstar shows this code
DLC/DLF series, 2015 and later (Midea-built): The code appears on the indoor unit's LED display in place of the set temperature. Some models also blink the indicator lamps in a pattern that matches the code. E codes are faults in the indoor unit or its communication link, F codes are faults on the outdoor side, and P codes are protections: the outdoor unit has stopped itself to prevent damage. EC is the refrigerant leak check.
Other Tempstar codes
Same part of the system as P3:
P3 on other brands
The same characters do not always mean the same thing. Check the brand on your unit.
- Pioneer P3 Outdoor temperature too low protection (heating lockout) / Compressor current overload protection (outdoor display)
- Blueridge P3 Outdoor temperature too low protection (heating lockout)
- Zone Air P3 Other protection (unspecified)
- ACiQ P3 Outdoor temperature too low protection (heating lockout) / Other protection (unspecified)
Questions people ask
Can I reset a Tempstar P3 code myself?
Yes. Turn the system off at the breaker for five minutes, then restart it. If P3 comes back, the fault is real and needs the checks above.
Is it safe to keep running a Tempstar showing P3?
Not repeatedly. A protection code means the unit stopped itself to prevent damage, and resetting it over and over can turn a cheap repair into a compressor failure. Reset once, check the basics, and stop if it returns.
Do I need a technician for Tempstar P3?
You can almost always clear this yourself with the steps below. No technician needed unless the code appears at temperatures well inside the rated range.
Sources
- ICP DLCSRA Outdoor Unit Single Zone Ductless Service Manual 32808000801 (error code table)
- ICP ductless installation instructions IM-KSAIC04-04 (DLCPRA / DLCSRB / DLCERB / DLCLRA error codes)
- ICP R-410A Ductless Split System Service Manual 421 01 9204 00 (DLC4 / DLF4, 2013)
Updated September 2026. Codes and definitions vary by model year. If your manual disagrees with this page, your manual wins. Send a correction.